Type TL Rated
Substitution to be test exempt
Model Number | Watts | Input Voltage | Output Type | Output Current | Output Voltage | Dimensions (L x W x H x M) |
Spec Sheet | COAs | |
---|---|---|---|---|---|---|---|---|---|
AC-25CD1.25BPME AC-25CD1.25BPMV, AC25CD1.25BPBME Bottom Mount |
25 Watts | 347 Volts | Constant Current | 350mA - 1250mA | 15 - 55 Volts | 5.23 x 2.48 x 1.18 x 4.84 |
![]() |
||
AC-25CD1.25APUN AC25CD1.25APBUM, Programmable |
25 Watts | 120 - 277 Volts | Constant Current | 350mA - 1250mA | 11-55 Volts | 6.22" x 1.73" x 1.22" x 5.86" |
![]() |
||
AC25CD1.25APBME Programmable Bottom Mount |
25 Watts | 120-277 Volts | Constant Current | 350mA - 1250mA | 15 - 55 Volts | 4.56" x 2.48" x 1.18" |
![]() |
||
AC30CD1.25BPBY0 Programmable |
30 Watts | 120-277 Volts | Constant Current | 350mA - 1250mA | 15-55 Volts | 4.56" x 2.48" x 1.18" |
![]() |
||
AC-40CD1.1BRLZ Type TL Rated |
40 Watts | 347 Volts | Constant Current | 600mA 1100mA | 28-36 Volts | 12.4" x 1.3" x 1.1" x 11.8" |
![]() |
||
AC-40CD1.4BPKV AC-40CD1.4BPMZ AC-40CD1.4BPBKV Bottom Mount AC-40CD1.4BPBMZ Bottom Mount |
40 Watts | 347 Volts | Constant Current | 400mA - 1400mA | 15 - 55 Volts | 5.23 x 2.48 x 1.18 x 4.84 |
![]() |
||
AC-40CD1.1ARDN |
40 Watts | 120 - 277 Volts | Constant Current | 600mA - 1100mA | 28 - 36 Volts | 12.4" x 1.3" x 1.08" x 11.8" |
![]() |
||
AC40CD1.05APU3 Programmable |
40 Watts | 120-277 Volts | Constant Current | 250mA-1050mA | 23-38 Volts | 6.22" x 1.73" x 1.22" 5.86" |
![]() |
||
AC-50CD1.4BPTC6 Programmable |
50 Watts | 347 Volts | Constant Current | 400mA - 1400mA | 15 - 55 Volts | 12.4" x 1.3" x 1.08" x 11.8" |
![]() |
||
AC50CD1.4APE1L Programmable |
50 Watts | 120-277 Volts | Constant Current | 400mA - 1400mA | 15-40 Volts | 4.56" x 2.48" x 1.18" |
![]() |
||
AC-50CD1.4APBNZ Programmable |
50 Watts | 120 - 277 Volts | Constant Current | 400mA - 1400mA | 15 - 55 Volts | 4.56" x 2.48" x 1.18" |
![]() |
||
AC-D54C1.5ARDM |
54 Watts | 120-277V | Constant Current | 1000mA - 1500mA | 28-36 Volts | 12.4" x 1.3" x 1.1" x 11.8" |
![]() |
||
AC-54CD1.5BRMA Type TL Rated |
54 Watts | 347 Volts | Constant Current | 1000mA to 1500mA | 28-36 Volts | 12.4" x 1.3" x 1.1" x 11.8" |
![]() |
||
AC-54CD1.5ARNT Type TL Rated |
54 Watts | 120-277 | Constant Current | 1500mA | 36 Volts | 12.4 x 1.3 x 1.1 x 11.8 |
![]() |
||
AC-65CD1.75AMG |
65 Watts | 277 Volts | Constant Current | 1750mA | 37 | 15.55 x 1.49 x 1.06 x 15.23 |
![]() |
||
AC-80CD2.2BRMD |
80 Watts | 347 Volts | Constant Current | 1500mA to 2200mA | 28-36 Volts | 15.55" x 1.49" x 1.06" x 15.23" |
![]() |
||
AC-80CD2.1AJTL Programmable |
80 Watts | 120 - 277 volts | Constant Current | 1050mA - 2100mA | 27 - 55 Volts | 15.55" x 1.49" x 1.08" x 15.23" |
![]() |
||
AC-80CD2.1APVQ Programmable |
80 Watts | 120-277 Volts | Constant Current | 1050mA-2100mA | 27-55 Volts | 9.5" x 2.4" x 1.46" x 8.9" |
![]() |
||
AC85CD2.6AP0L Programmable |
85 Watts | 120-277 Volts | Constant Current | 750mA - 2600mA | 27-55 Volts | 15.55" x 1.49" x 1.08" x 15.23" |
![]() |
||
AC-98CD2.1APTMX Programmable |
98 Watts | 120 - 277 Volts | Constant Current | 1050mA - 2100mA | 27 - 55 Volts | 9.5 x 2.4 x 1.46 x 8.9 |
![]() |
||
AC-98CD2.75APUR Programmable |
98 Watts | 120 - 277 Volts | Constant Current | 1400mA - 2750mA | 27-55 Volts | 15.55" x 1.49" x 1.08" x 15.23" |
![]() |
||
AC-98CD2.1APEJ7 Programmable |
98 Watts | 120-277 Volts | Constant Current | 1050mA - 2100mA | 27-55 Volts | 6.85" x 3.58" x 1.73" x 6.42" |
![]() |
||
AC98CD2.1APB1M Programmable |
98 Watts | 120-277 Volts | Constant Current | 1050mA - 2100mA | 28-46 Volts | 9.5" x 2.4" x 1.46" x 8.9" |
![]() |
||
AC-98CD2.75AP0N Programmable |
98 Watts | 120-277 Volts | Constant Current | 1400mA - 2750mA | 27-55 Volts | 6.85" x 3.58" x 1.73" x 6.42" |
![]() |
The advantage the TL program adds is the ability for the substitution to be test exempt (assuming the ratings check out). Before the TL program nearly every alternate construction submittal would require samples and testing. The TL program eliminates the need for samples and reduces alternate construction costs and turnaround time.
As long as the following conditions are met, there is no testing needed, This may be submitted as a paper work change only.
- The alternate Type TL driver input current and input power ratings are equal or lower than that of the original Type TL driver ratings,
- When the Type TL LED driver is a constant current output type, the alternate Type TL driver output current setting (if adjustable) or rating (if not adjustable) should be equal or lower than that of the original TL driver;
- When the Type TL driver is a constant voltage output type, the alternate Type TL driver output voltage rating should be equal to or lower than that of the original TL driver;
- The alternate TL driver output power setting (if adjustable) or rating (if not adjustable) should be equal or higher than that of the original TL driver;
- The alternate Type TL driver should have a Tref max equal to or higher than the temperature observed at Tc point on the original Type TL driver,
- The alternate Type TL driver should have a Measured Tref equal to or lower than the Measured Tref on the original Type TL driver,
Key Benefits:
- As low as 1mA tuning. Improves binning & increases system efficiency
- Wide output voltage and current range allows you to reduces driver inventory
- UL TL Rated: Limits additional fixture testing
- Free factory Pre-Programming available
- 0-10V dimming
Key Features:
- We ONLY use "Long Life" Japanese capacitors for maximum reliability and longevity
- American Warrantee Support and Customer Service
WP 20141119 001
Phone Instructions
First you must have a Android device (phone/tablet) with NFC-V app downloaded. After the customers download NFC-V app, the application might not active. To solve this, the customer need to check the setting on their device and allow NFC data exchange. Please follow the video instructions.
Phone Instructions - Spanish
First you must have a Android device (phone/tablet) with NFC-V app downloaded. After the customers download NFC-V app, the application might not active. To solve this, the customer need to check the setting on their device and allow NFC data exchange. Please follow the video instructions.